M31-AXXX8000G 8DI M31 series distributed IO host supports Modbus TCP protocol and Modbus RTU protocol for acquisition control

[Introduction]:The M31 series distributed IO host supports Modbus TCP protocol and Modbus RTU protocol for acquisition control. The device supports simultaneous access by 5 clients and supports function codes 01/02/03/04/05/06/15/16. The product adopts an scalable design in structure. During use, if the user finds that the current device has some functions When the needs cannot be met, you can select the corresponding IO expansion modules according to the missing functions and splice them together to achieve the functions. There is no need to purchase the whole machine. This saves costs and facilitates customers to access the current on-site environment; the modules are self-contained. With status diagnosis function, it can monitor the communication status of IO modules in real time; it can support a maximum of 16 IO expansion modules.

pin
SymbolnameFunction /Description
DllDll switch inputDll switch input interface, used in conjunction with C0M1
C0M1COM terminal of DllCOM side ofDIl
DI2DI2 switch inputDI2 switch input interface, used in conjunction with COM2
COM2COM side of DI2COM2 end ofDI2
DI3DI3 switch inputDI3 switch input interface, used in conjunction with COM3
COM3COM side of DI3COM side of DI3
DI4DI4 switch inputDI4 switch input interface, used in conjunction with COM4
COM4COM side of DI4COM side of DI4
DI5DI5 switch inputDll switch input interface, used in conjunction with COMS
COM5COM side of DI5COM side of DI5
DI6DI6 switch inputDI6 switch input interface, used in conjunction with CO\I6
C0M6COM side of DI6COM side of DI6
DI7DI7 switch inputDI7 switch input interface, used in conjunction with C0M7
COM7COM side of DI7COM side of DI7
DI8DIS switch inputDI8 switch input interface, used in conjunction with C0M8
COM8COM side of DI8COM side of DIS
VO+Power output positive poleThe positive pole of the power supply output is consistent with the power supply voltage of the device.
VO+Power output positive poleThe positive pole of the power supply output is consistent with the power supply voltage of the device.
VO-Power output negative poleThe negative pole of the power supply output is the same as the power supply voltage of the device.
ReloadFactory reset auto-negotiationPress and hold for 5-10 seconds to restore factor}- settings; double-click within 2 seconds to automatically negotiate the expansion module
A(RS485)RS485 A interfaceRS485 A interface
B(RS485)RS485 B interfaceRS485 B interface
G(RS485)RS485G interfaceRS485G interface
PEgroundground
V-(DC9-36 V)Negative pole of power supplyDC (9-3 6V) power supply negative interface
V+ (DC9-36 V)Positive pole of power supplyDC (9-3 6V) power supply positive interface
LAN1Network portStandard RJ45 network cable interface