Home >

M31-AAAX4440G 4DI,4AI,4DO M31 series distributed IO host supports Modbus TCP protocol and Modbus RTU protocol for acquisition control

[Introduction]:M31 series distributed IO host supports Modbus TCP protocol and Modbus RTU protocol for acquisition control. The device supports simultaneous access by 5 clients and supports function codes 01/02/03/04/05/06/15/16. The product adopts an scalable design in structure. During use, if the user finds that the current device has some functions When the needs cannot be met, you can select the corresponding IO expansion modules according to the missing functions and splice them together to achieve the functions. There is no need to purchase the whole machine. This saves costs and facilitates customers to access the current on-site environment; the modules are self-contained. With status diagnosis function, it can monitor the communication status of IO modules in real time; it can support a maximum of 16 IO expansion modules.

PIN
SymbolnameFunction/Description
AllAll analog inputAll analog input interface, used in conjunction with COMA
AI2AI2 analog inputAI2 analog input interface, used in conjunction with COMA
AI3AI3 analog inputAI3 analog input interface, used in conjunction with COMA
AI4AI4 analog inputAI4 analog input interface, used in conjunction with COMA
COMAAl analog input common terminalAI1-AI4 share the COMA public terminal
DllDll switch inputDll switch input interface, used in conjunction with COMB
DI2DI2 switch inputDI2 switch input interface, used in conjunction with COMB
COMBDI switch input common terminalDI1-DI2 share the CONfB common terminal
DI3DI3 switch inputDI3 switch input interface, used in conjunction with COMC
DI4DI4 switch inputDI4 switching input interface, used in conjunction with COMC
COMCDI switch input common terminalDI3-DI4 share the COMC common port
DOIDOI switch outputDOI switching output interface, used in conjunction with C0M1
COMICOM terminal of DOICOM terminal of DOI
DO2DO2 switch outputDO2 switch output interface, used in conjunction with COM2
COMCOM terminal ofDO2COM terminal ofDO2
DO3DO3 switch outputDO3 switching output interface, used in conjunction with COM3
COM3COM terminal ofDO3COM terminal ofDO3
DO4DO4 switch outputDO4 switching output interface, used in conjunction with COM4
COM4COM terminal ofDO4COM terminal ofDO4
ReloadFactory reset auto-negotiationPress and hold for 5-10 seconds to restore factor}- settings; double-click within 2 seconds to automatically negotiate the expansion module
A(RS485)RS485 A interfaceRS485 A interfacs
B(RS485)RS485 B interfaceRS485 B interface
G(RS485)RS485G interfaceRS485G interface
PEgroundground
V-(DC9-36V)Negative pole of power supplyDC (9-36V) power supply negative interface
V+ (DC9-36V)Positive pole of power supplyDC (9-3 6V) power supply positive interface