Home >
K61-DL20 Switching Value Synchronous Remote Transmission

[Introduction]:This product is a cross-communication function product. Function: The sender collects 4-channel switch signal and transmits the data to the receiver through wireless (LoRa spread spectrum) or network port, and the receiver restores the 4-channel switch signal.

0
No. Port and Other Definitions Function Receiving Description
1 PE Protective earth terminal Lightning protection grounding. If the ground lead is good, it is recommended to connect the product case to the ground; vice versa.
2 + Positive power supply The power input is positive, and the DC input voltage range is 8-28V.
3 - Power ground Power input negative (0V).
4 B/RX Communication interface B/RXD RS485 interface B/(RS232_RXD).
5 A/TX Communication interface A/TXD RS485 interface A/(RS232_TXD).
6 G Communication port RS485 ground (can not be connected)/RS232 signal ground (0V).
7 Second communication interface Antenna port/network port 433Mhz antenna port/network port socket
8 NO1 Switch output channel 1 The relay is normally open contact output, and the contact current is less than or equal to 3A.
9 COM1 Public 1 Common terminal of relay output channel 1.
10 NO2 Switch output channel 2 The relay is normally open contact output, and the contact current is less than or equal to 3A.
11 COM2 Public 2 Common terminal of relay output channel 2.
12 NO3 Switch output channel 3 The relay is normally open contact output, and the contact current is less than or equal to 3A.
13 COM3 Public 3 Common terminal of relay output channel 3.
14 NO4 Switch output channel 4 The relay is normally open contact output, and the contact current is less than or equal to 3A.
15 COM4 Public 4 Common terminal of relay output channel 4.
16 - None Leave it in the air, do not connect.
17 SFR Reset Press and hold for 3 seconds to restore the factory settings (Set Factory Reset) (indicated by the status of the RUN light).
18 SIM SIM card slot Insert a data IoT card and a phone card with a data plan. (This product has no SIM card slot)
1
No. Port and Other Definitions Function Sending Description
1 PE Protective earth terminal Lightning protection grounding. If the ground lead is good, it is recommended to connect the product case to the ground; vice versa.
2 + Positive power supply The power input is positive, and the DC voltage input range is DC8-28V.
3 - Power ground Power input negative (0V).
4 B/RX Communication interface B/RXD RS485 interface B/(RS232_RXD).
5 A/TX Communication interface A/TXD RS485 interface A/(RS232_TXD).
6 G Communication port RS485 ground (can not be connected)/RS232 signal ground (0V).
7 Second communication interface Antenna port/network port 433Mhz antenna port/network port socket
8 DI1 Switch value acquisition channel 1 Switch signal acquisition channel 1. With GND: dry contact input is closed and valid; wet contact is less than 0.7V valid.
9 GND Input negative Input negative (0V).
10 DI2 Switch value acquisition channel 2 Switch signal acquisition channel 2. With GND: dry contact input is closed and valid; wet contact is less than 0.7V valid.
11 GND Input negative Input negative (0V).
12 DI3 Switch value acquisition channel 3 Switch signal acquisition channel 3. With GND: dry contact input is closed and valid; wet contact is less than 0.7V valid.
13 GND Input negative Input negative (0V).
14 DI4 Switch value acquisition channel 4 Switch signal acquisition channel 4. With GND: dry contact input is closed and valid; wet contact is less than 0.7V valid.
15 GND Input negative Input negative (0V).
16 - None Leave it in the air, do not connect.
17 SFR Reset Press and hold for 3 seconds to restore the factory settings (Set Factory Reset) (indicated by the status of the RUN light).
18 SIM SIM card slot Insert a data IoT card or a phone card with a sufficient data plan.(This product has no SIM card slot)