Home >
E810-R18 RS485 Hub 1-channel RS-485 to 8-channel RS-485 isolated repeater (HUB) Industrial EMC level 3 Optical isolation

[Introduction]:E810-R18 is an isolated repeater (HUB) for 1-channel RS-485 to 8-channel RS-485 launched by Ebyte. RS485 hub is a communication device that supports 1-channel RS-485 master device and 8-channel RS-485 slave devices. Photoelectric isolation technology is used to protect the master and slave devices from interference. No configuration is required, and transparent data transmission between the master and slave interfaces. This product is suitable for comprehensive RS485 communication systems such as automation control systems, monitoring systems, alarms, access control systems, IC card charging, meter reading, one-card pass, parking lot charging, etc.

PIN
No. Name Description
1IN-485A3.81mm terminal block, RS485 input A interface
2IN-485B3.81mm terminal block, RS485 input B interface
3IN-GND3.81mm terminal block, input digital signal ground
4CH5-485A3.81mm terminal block, CH5 output A interface
5CH5-485B3.81mm terminal block, CH5 output B interface
6GND3.81mm terminal block, output digital signal ground
7CH6-485A3.81mm terminal block, CH6 output A interface
8CH6-485B3.81mm terminal block, CH6 output B interface
9CH7-485A3.81mm terminal block, CH7 output A interface
10CH7-485B3.81mm terminal block, CH7 output B interface
11GND3.81mm terminal block, output digital signal ground
12CH8-485A3.81mm terminal block, CH8 output A interface
13CH8-485B3.81mm terminal block, CH8 output B interface
14CH4-485A3.81mm terminal block, CH8 output A interface Interface
15CH4-485B3.81mm terminal block, CH8 output B interface
16GND3.81mm terminal block, output digital signal ground
17CH3-485A3.81mm terminal block, CH3 output A interface
18CH3-485B3.81mm terminal block, CH3 output B interface
19CH2-485A3.81mm terminal block, CH2 output A interface
20CH2-485B3.81mm terminal block, CH2 output B interface
21GND3.81mm terminal block, output digital signal ground
22CH1-485A3.81mm terminal block, CH1 output A interface
23CH1-485B3.81mm terminal block, CH1 output B interface
24DC 9~40V-VCC3.81mm terminal block, power input positive pole
25DC 9~40V-GND3.81mm terminal block, power ground, signal ground not interoperable with digital signal ground
26PE3.81mm terminal block, earth terminal
27LED-PWRPower indicator light
28LED-TXDMain serial port data sending indicator light
29LED-RXDMain serial port data receiving indicator light
30LED-CH1CH1 data sending indicator light
31LED-CH2CH2 data sending indicator light
32LED-CH3CH3 data sending indicator light
33LED-CH4CH4 Data sending indicator light
34LED-CH5CH5 Data sending indicator light
35LED-CH6CH6 Data sending indicator light
36LED-CH7CH7 Data sending indicator light
37LED-CH8CH8 Data sending indicator light